Bag Filter Leak Detector Dust Analyzer with 0.1μm–400μm Particle Size Range and ≤260℃ / 400℃ / 800℃ Gas Temperature Options

Nanjing Juge Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Bag Filter Leak Detector Dust Analyzer with 0.1μm–400μm Particle Size Range and ≤260℃ / 400℃ / 800℃ Gas Temperature Options

‌Pipeline Gas Flow Velocity‌ : 1m/s to 30m/s

Price : USD100-500

MOQ : 1 Unit

‌Dust Particle Size Range‌ : Nominal 0.1μm–400μm (signals outside this range are detectable with varying characteristics)

Supply Ability : 1000 Unit/Week

Packaging Details : Neutral carton

Range : 0–50, 100, 200, 5000, 20,000 mg/m³ (custom ranges available)

‌Transmitter Power Supply‌ : 15–32VDC or configurable 220V supply

Model Number : AG600-JD

Brand Name : JUGE

Delivery Time : 5-8 working days

‌Pipeline Gas Pressure‌ : -0.1 to 2MPa

Certification : IOS9001, CE

Payment Terms : T/T

Name : Bag Filter Leak Detector

Place of Origin : Nanjing, China

‌Probe Structure‌ : 400mm / 800mm (standard); 200mm, 600mm, 750mm, 1000mm (customizable)

‌Pipeline Gas Temperature‌ : ≤260℃ / 400℃ / 800℃ (options)

Contact Now

Bag Filter Leak Detector Insertion Type Dust Analyzer
Product Overview
The dust concentration analyzer adopts the world's advanced AC coupling technology, utilizing precise and reliable electrostatic measurement principles. When dust particles pass through the sensor, their weak charges are captured and transmitted to the processor. The processor converts these signals into output values linearly correlated with dust concentration, enabling real-time online monitoring. Widely applied in power generation, metallurgy, cement production, chemicals, food processing, and other industries.
Key Features
  • Robust Structure: Composed of a sensor unit and transmitter unit for high anti-interference performance.
  • Durable Electrode Design: Special material coating ensures superior high-temperature resistance, corrosion resistance, and anti-adhesion capabilities.
  • Sealed Construction: Optimized housing design with airtight connectors prevents gas leakage and protects electrodes from external impacts.
  • Automatic Zero Calibration: Transmitter features self-zeroing to eliminate data drift.
  • Polarity-Free Power Supply: Operates on non-polarized DC-24V, preventing equipment damage from wiring errors.
  • Efficient Leak Detection: Replaces manual inspection and guides dust removal/emission control.
  • Linear Signal Output: Two-wire system (4-20mA) ensures strong noise immunity and long-distance transmission.
  • No special cable requirements.
  • Current output linearly correlates with dust concentration for seamless PLC integration.
Technical Specifications
Parameter Specification
Operating Ambient Temperature -20℃ to 60℃ (electronic components)
Operating Ambient Humidity ≤90% non-condensing
Operating Ambient Vibration Maximum continuous vibration in any direction and frequency: RMS 2g (20m/s²)
Operating Ambient Electromagnetic Field Maximum at 50 Hz = 60A/m (equivalent to a 50AT field in a 1m×1m square coil)
Operating Environmental Protection Protection rating: IP65/NEMA4 (aluminum alloy housing, suitable for non-corrosive environments; stainless steel probe)
Pipeline Gas Pressure -0.1 to 2MPa
Pipeline Gas Flow Velocity 1m/s to 30m/s
Pipeline Gas Temperature ≤260℃ / 400℃ / 800℃ (options)
Probe Structure 400mm / 800mm (standard); 200mm, 600mm, 750mm, 1000mm (customizable)
Dust Particle Size Range Nominal 0.1μm-400μm (signals outside this range are detectable with varying characteristics)
Zero Drift (Time) <1% of range annually
(Temperature) <1% of range within specified temperature limits
Full-Scale Drift (Time) <1% of range annually
Circuit Stability All components use high-stability electronic assemblies
Noise Immunity All 50/60Hz noise and harmonics are filtered prior to signal reception
Measurement Range 0-50, 100, 200, 5000, 20,000 mg/m³ (custom ranges available)
Transmitter Output Two-wire 4-20mA; optional relay output; audible/visual alarm
Transmitter Power Supply 15-32VDC or configurable 220V supply

Product Tags:

32V fixed gas monitor

      

Insertion Type fixed gas monitor

      

32V fixed h2s monitor

      
Buy cheap Bag Filter Leak Detector Dust Analyzer with 0.1μm–400μm Particle Size Range and ≤260℃ / 400℃ / 800℃ Gas Temperature Options product

Bag Filter Leak Detector Dust Analyzer with 0.1μm–400μm Particle Size Range and ≤260℃ / 400℃ / 800℃ Gas Temperature Options Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Nanjing Juge Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)